Basic Info.
Model NO.
buried power cable
Application
Construction, Underground, Industrial, Power Station
Voltage
Low and Medium Voltage Cable
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS
Factory
30 Years Production Experience
Main Product01
High Voltage, Medium Voltage and Low Voltage Power
Main Product02
House/Building Electrical Wires
Main Product03
Aerial Cable AAC/AAAC/ACSR/ABC Cable
Main Product04
Control Cable/ Instrument Cable
Main Product05
Optical Fiber Cable
Specification
IEC standard, CE ISO ROHS CCC
Product Description
low voltage buried power cable
This product is suitable for AC rated voltage 1.8/3kv and under transmission line.
Physical and mechanical properties and electric performance accord with GB/T12706-2008 and IEC60502-2005 and IEC60840-2004.
Operating characteristic of control cable
1)laying temperature:≥0ºC
2)The continuous permissible operating temperature of conductors shall not exceed 90 ºC.
3)During short circuit (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250ºC
4)Bending Radius:
single core cable:20D
multi-core cable:15D(D=diameter)
Specification of control cable
model number | laying occasion |
copper core | aluminum core |
YJV | YJLV | indoor/tunnel,pipeline, |
YJY | YJLY |
YJV22 | YJLV22 | adapt to underground laying,not adapt to pipeline laying |
YJV23 | YJLV23 |
YJV32 | YJLV32 | laying in river or shallow sea bed,as a cross river or wire between petroleum and natural gas platform,also used for high divided lands areas |
YJV33 | YJLV33 |
YJV42 | YJLV42 |
YJV43 | YJLV43 |
Range of production
core /area/rated voltage | 0.6/1 | 1.8/3 |
single core 1 | 1.5-1000 | 10-1000 |
double core 2 | 1.5-240 | 10-240 |
three core 3 | 1.5-300 | 10-300 |
core3+2 | 2.5-300 | 10-300 |
Notes:core number,cross section depends on cable type,voltage.
0.6/1kv,1.8/3kv using warm water cross-linking method or radiation cross-linking method.
0.6/1kv XLPE/PVC POWER CABLE(steel wire armored) YJV32,YJLV32 | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
sectional area of conductor (mm²) | thickness of insulation(mm) | armored cable |
thickness of isolation cover | armored wire overall diameter | thickness of sheath | overalldiameter |
mm | mm | mm | mm |
2c | 3c | 4c | 5c | 2c | 3c | 4c | 5c | 2c | 3c | 4c | 5c | 2c | 3c | 4c | 5c |
1.5 | 0.7 | 1 | 1 | 1 | 1 | 0.8 | 0.8 | 0.8 | 0.8 | 1.8 | 1.8 | 1.8 | 1.8 | 14.2 | 14.6 | 15.3 | 16.1 |
2.5 | 0.7 | 1 | 1 | 1 | 1 | 0.8 | 0.8 | 0.8 | 0.8 | 1.8 | 1.8 | 1.8 | 1.8 | 15 | 15.4 | 16.3 | 17.2 |
4 | 0.7 | 1 | 1 | 1 | 1 | 0.8 | 0.8 | 0.8 | 1.25 | 1.8 | 1.8 | 1.8 | 1.8 | 15.9 | 16.5 | 17.4 | 19.4 |
6 | 0.7 | 1 | 1 | 1 | 1 | 0.8 | 0.8 | 1.25 | 1.25 | 1.8 | 1.8 | 1.8 | 1.8 | 16.9 | 17.6 | 19.5 | 20.7 |
10 | 0.7 | 1 | 1 | 1 | 1 | 1.25 | 1.25 | 1.25 | 1.25 | 1.8 | 1.8 | 1.8 | 1.8 | 20.1 | 20.9 | 22.3 | 23.8 |
16 | 0.7 | 1 | 1 | 1 | 1 | 1.25 | 1.25 | 1.6 | 1.6 | 1.8 | 1.8 | 1.8 | 1.8 | 22.3 | 23.3 | 25.6 | 27.5 |
25 | 0.9 | 1 | 1 | 1 | 1 | 1.6 | 1.6 | 1.6 | 1.6 | 1.8 | 1.8 | 1.8 | 1.8 | 25.8 | 27 | 29 | 31.3 |
35 | 0.9 | 1 | 1 | 1 | 1 | 1.6 | 1.6 | 1.6 | 1.6 | 1.8 | 1.8 | 1.9 | 1.9 | 28.2 | 29.6 | 32.1 | 34.7 |
50 | 1 | 1 | 1 | 1 | 1.2 | 1.6 | 1.6 | 1.6 | 2 | 1.8 | 1.9 | 2 | 2.1 | 31 | 32.8 | 35.7 | 40.1 |
70 | 1.1 | 1 | 1.2 | 1.2 | 1.2 | 1.6 | 2 | 2 | 2 | 2 | 2 | 2.2 | 2.3 | 28.2 | 32.9 | 37.4 | 43.6 |
95 | 1.1 | 1.2 | 1.2 | 1.2 | 1.4 | 2 | 2 | 2 | 2.5 | 2.1 | 2.2 | 2.3 | 2.5 | 32.4 | 36.5 | 41.6 | 49.5 |
120 | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 2 | 2.5 | 2.5 | 2.5 | 2.2 | 2.3 | 2.5 | 2.6 | 35.4 | 39.8 | 46.4 | 53.9 |
150 | 1.4 | 1.2 | 1.4 | 1.4 | 1.4 | 2 | 2.5 | 2.5 | 2.5 | 2.3 | 2.5 | 2.7 | 2.8 | 38.2 | 45.4 | 50.6 | 59.5 |
185 | 1.6 | 1.4 | 1.4 | 1.4 | 1.6 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.6 | 2.8 | 3 | 46 | 49.6 | 55.4 | 68.2 |
240 | 1.7 | 1.4 | 1.6 | 1.6 | 1.6 | 2.5 | 2.5 | 2.5 | 3.15 | 2.7 | 2.8 | 3 | 3.3 | 50.8 | 57 | 62.9 | 74.2 |
300 | 1.8 | 1.6 | 1.6 | 1.6 | 1.8 | 2.5 | 2.5 | 2.5 | 3.15 | 2.9 | 3 | 3.2 | 3.5 | 56 | 59.7 | 69 | 79.7 |
400 | 2 | | 1.6 | 1.8 | | | 2.5 | 3.15 | | | 3.3 | 3.6 | | | 66.8 | 79.9 | |
500 | 2.2 | | 1.8 | | | | 3.15 | | | | 3.5 | | | | 85.5 | | |
| | | | | | | | | | | | | | | | | |
0.6/1kv XLPE/PVC POWER CABLE(steel belt armored) YJV22,YJLV22 | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
sectional area of conductor (mm²) | thickness of insulation(mm) | steel belt armored cable |
thickness of isolation cover | thickness of armored belt | thickness of sheath | overalldiameter |
mm | mm | mm | mm |
2c | 3c | 4c | 5c | 2c | 3c | 4c | 5c | 2c | 3c | 4c | 5c | 2c | 3c | 4c | 5c |
1.5 | 0.7 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 11.8 | 12.2 | 12.9 | 13.7 |
2.5 | 0.7 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 12.6 | 13 | 13.9 | 14.8 |
4 | 0.7 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 13.5 | 14.1 | 15 | 16.1 |
6 | 0.7 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 14.5 | 15.2 | 16.2 | 17.4 |
10 | 0.7 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 16.8 | 17.6 | 19 | 20.5 |
16 | 0.7 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 19 | 20 | 21.6 | 23.5 |
25 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.8 | 21.8 | 23 | 25 | 27.3 |
35 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.8 | 1.9 | 24.2 | 25.6 | 27.9 | 30.7 |
50 | 1 | 0.9 | 0.9 | 0.9 | 0.9 | 0.2 | 0.2 | 0.2 | 0.2 | 1.8 | 1.8 | 1.9 | 2 | 27 | 28.6 | 31.5 | 34.7 |
70 | 1.1 | 0.9 | 0.9 | 0.9 | 1.2 | 0.2 | 0.2 | 0.2 | 0.5 | 1.9 | 2 | 2.1 | 2.2 | 24 | 27.7 | 32 | 40 |
95 | 1.1 | 0.9 | 1.2 | 1.2 | 1.2 | 0.2 | 0.5 | 0.5 | 0.5 | 2 | 2.2 | 2.3 | 2.4 | 27 | 33.1 | 38.2 | 44.1 |
120 | 1.2 | 1.2 | 1.2 | 1.2 | 1.4 | 0.5 | 0.5 | 0.5 | 0.5 | 2.2 | 2.3 | 2.4 | 2.6 | 32 | 36.4 | 41 | 48.7 |
150 | 1.4 | 1.2 | 1.2 | 1.4 | 1.4 | 0.5 | 0.5 | 0.5 | 0.5 | 2.3 | 2.4 | 2.6 | 2.7 | 34.8 | 40 | 45.6 | 54.5 |
185 | 1.6 | 1.2 | 1.2 | 1.4 | 1.4 | 0.5 | 0.5 | 0.5 | 0.5 | 2.4 | 2.6 | 2.7 | 2.9 | 40.6 | 44.4 | 50.4 | 62.8 |
240 | 1.7 | 1.4 | 1.4 | 1.4 | 1.4 | 0.5 | 0.5 | 0.5 | 0.5 | 2.6 | 2.7 | 2.9 | 3.1 | 45.8 | 51.6 | 57.5 | 67.3 |
300 | 1.8 | 1.4 | 1.4 | 1.4 | 1.4 | 0.5 | 0.5 | 0.5 | 0.5 | 2.8 | 2.9 | 3.1 | 3.4 | 50.6 | 54.3 | 63.6 | 72.6 |
400 | 2 | | 1.4 | 1.4 | | | 0.5 | 0.5 | | | 3.2 | 3.4 | | | 61.4 | 72.6 | |
500 | | | 1.4 | | | | 0.5 | | | | 3.4 | | | | 78.4 | | |
0.6/1kv XLPE/PVC POWER CABLE(steel wire armored) YJV32,YJLV32 | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | |
sectional Area of Conductor (mm²) | Thickness of insulation (mm) | armored cable | |
thickness of isolation cover | armored wire overall diameter | thickness of sheath | overalldiameter |
mm | mm | mm | mm |
phase line | zero line | phase line | zero line | 3+1c | 3+2c | 4+1c | 3+1c | 3+2c | 4+1c | 3+1c | 3+2c | 4+1c | 3+1c | 3+2c | 4+1c |
2.5 | 1.5 | 0.7 | 0.7 | 1 | 1 | 1 | 0.8 | 0.8 | 0.8 | 1.8 | 1.8 | 1.8 | 16.1 | 16.8 | 17 |
4 | 2.5 | 0.7 | 0.7 | 1 | 1 | 1 | 0.8 | 1.25 | 1.25 | 1.8 | 1.8 | 1.8 | 17.1 | 18.8 | 19.1 |
6 | 4 | 0.7 | 0.7 | 1 | 1 | 1 | 1.25 | 1.25 | 1.25 | 1.8 | 1.8 | 1.8 | 19.3 | 20.2 | 20.5 |
10 | 6 | 0.7 | 0.7 | 1 | 1 | 1 | 1.25 | 1.25 | 1.25 | 1.8 | 1.8 | 1.8 | 21.6 | 22.6 | 23.2 |
16 | 10 | 0.7 | 0.7 | 1 | 1 | 1 | 1.25 | 1.6 | 1.6 | 1.8 | 1.8 | 1.8 | 24.3 | 26.3 | 26.9 |
25 | 16 | 0.9 | 0.7 | 1 | 1 | 1 | 1.6 | 1.6 | 1.6 | 1.8 | 1.8 | 1.8 | 28.2 | 29.7 | 30.5 |
35 | 16 | 0.9 | 0.7 | 1 | 1 | 1 | 1.6 | 1.6 | 1.6 | 1.8 | 1.8 | 1.9 | 30.4 | 31.7 | 33.3 |
50 | 25 | 1 | 0.9 | 1 | 1 | 1.2 | 1.6 | 1.6 | 2 | 1.9 | 2 | 2.1 | 34 | 35.9 | 38.7 |
70 | 35 | 1.1 | 0.9 | 1.2 | 1.2 | 1.2 | 2 | 2 | 2 | 2.1 | 2.1 | 2.2 | 36.9 | 40.4 | 41.6 |
95 | 50 | 1.1 | 1 | 1.2 | 1.2 | 1.2 | 2 | 2 | 2 | 2.2 | 2.3 | 2.4 | 40.4 | 45 | 46.1 |
120 | 70 | 1.2 | 1.1 | 1.2 | 1.4 | 1.4 | 2 | 2.5 | 2.5 | 2.4 | 2.5 | 2.6 | 43.7 | 50.8 | 52.8 |
150 | 70 | 1.4 | 1.1 | 1.4 | 1.4 | 1.4 | 2.5 | 2.5 | 2.5 | 2.5 | 2.6 | 2.7 | 48.9 | 55.1 | 57.1 |
185 | 95 | 1.6 | 1.1 | 1.4 | 1.4 | 1.6 | 2.5 | 2.5 | 2.5 | 2.7 | 2.8 | 2.9 | 54.6 | 60.6 | 62.9 |
240 | 120 | 1.7 | 1.2 | 1.6 | 1.6 | 1.6 | 2.5 | 2.5 | 2.5 | 2.9 | 3 | 3.1 | 62.6 | 68.2 | 69.7 |
300 | 150 | 1.8 | 1.4 | 1.6 | 1.6 | 1.6 | 2.5 | 2.5 | 3.15 | 3.1 | 3.2 | 3.4 | 67.9 | 75 | 74 |
400 | 185 | 2 | 1.6 | 1.6 | 1.8 | 1.8 | 3.15 | 3.15 | 3.15 | 3.4 | 3.5 | 3.7 | 78.6 | 85.5 | 79..3 |
1.8/3(3.6)kv XLPE/PVC single core (unarmored)YJV,YJLV | | | | | | |
| | | | | | |
conductor | thickness of insulation (mm) | copper tape screened (mm) | thickness of sheath(mm) | approx overall diameter (mm) |
sectional area(mm²) | structure | overall diameter (mm) |
10 | C.C. | 3.9 | 2 | 0.12 | 1.4 | 12.9 |
16 | C.C. | 5 | 2 | 0.12 | 1.4 | 14 |
25 | C.C. | 6 | 2 | 0.12 | 1.4 | 15 |
35 | C.C. | 7.2 | 2 | 0.12 | 1.4 | 16.2 |
50 | C.C. | 8.4 | 2 | 0.12 | 1.5 | 17.6 |
70 | C.C. | 10 | 2 | 0.12 | 1.5 | 19.2 |
95 | C.C. | 11.7 | 2 | 0.12 | 1.6 | 21.1 |
120 | C.C. | 13.1 | 2 | 0.12 | 1.6 | 22.5 |
150 | C.C. | 14.6 | 2 | 0.12 | 1.7 | 24.2 |
185 | C.C. | 16.3 | 2 | 0.12 | 1.7 | 25.9 |
240 | C.C. | 18.5 | 2 | 0.12 | 1.8 | 28.3 |
300 | C.C. | 20.7 | 2 | 0.12 | 1.9 | 30.7 |
400 | C.C. | 23.8 | 2 | 0.12 | 2 | 34 |
500 | C.C. | 26.6 | 2.2 | 0.12 | 2.1 | 37.4 |
630 | C.C. | 30.1 | 2.4 | 0.12 | 2.2 | 41.5 |
800 | C.C. | 35 | 2.6 | 0.12 | 2.3 | 47 |
1000 | S.S | 39.5 | 2.8 | 0.12 | 2.5 | 52.3 |
| | | | | | |
C.C. | circular compacted | | | | | |
S.S. | shaped stranded conductor | | | | | |
Address:
No. 68 Lishan North Road, Tianqiao District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
Company Introduction:
Shandong Yanggu Cable Group′s predecessor is Shandong Yanggu Cable Factory, was founded in 1986. Shandong Yanggu Cable Group is engaged in wire and cable high-tech research and production. Shandong Yanggu Cable Group is a high technology, high benefit State-owned large enterprises, One of the largest cable production base in China.
Shandong Yanggu Cable Group has plant area more than700, 000 square meters, has more than 2, 000 employees, hasthe Shandong Pacific Fiber Cable Co., Ltd., Nexans (Yanggu) New Rihui Limited, Yanggu Mingschin Copper Co., Ltd., Shandong Pacific Oaks Cable Ltd. And other holding companies.
Our Company has extensive manufacturing experience, strong technical capability, advanced equipment and well-appointed detection means. Company has main production equipment 860 (sets) and testing equipment 314 (Taiwan) sets. Which was imported successively from South Korea, Japan, the United States, Switzerland, Finland, Germany and other seven countries have the international leading level of the ultrahigh voltage and high voltage cross-linking cables, rubber sets of cables, fiber optic cable production line and testing equipment: Nokia of Finland, Troost of Germany is vertical and catenary cross-linking production line, three-layer co-extruded rubber cable PLCV120 UK production line, production line CCV90 Germany, Finland NEXTROM, Austria MS company, ROSSENDAHL company′s full range of cable production line, built to high 128.9 meters of vertical cross-linking pylons, Largest one in Asia is 500 kv power cables resonance test area, ensure the quality of the products reached the domestic leading level.